Brevis descriptio:

Type: anode x-ray tube
Applicationem: Pro generali diagnostica x-ray unit
Exemplar: KL25-0.6/1.5-110
Equivalent to CEI OX110-5
Integrated high quality vitrei tube


Product Detail

Payment & Shipping Terms:

Product Tags

Descriptio

KL25-0.6/1.5-110 tubus stationarius anode x-radius praesertim ad apparatum C-brachii destinatur et praesto est pro voltage tubo nominali cum magna frequentia vel DC generante.
Tubus qualitatis princeps integratus cum vitreo consilio duos maculas focales superpositas superpositas et anodem firmatas habet. Peculiaris designatio anode dat calorem elevatum dissipationis, quae ducit ad altiorem patientiam per put et vitam productam longiorem. Constans alta dosis cede per totam tubi vitam ab alta densitate tungsten praebetur. Otia integrationis in systematis productorum facilior est magnis technicis auxiliis.

Applications

KL25-0.6/1.5-110 maxime ad apparatum C-brachii destinatur et praesto est pro voltage tubo nominali cum DC generante.

Hic tubus umbilicum 1.5 et 0,6 umbilicum habet et pro maximo tubo voltage 110 kV praesto est.

 

Technica notitia

Nominal Tube Voltage 110kV
Nominal Focal Macula svir:0.6 magna:1.5(IEC60336/2005)
Filamentum Characteres svir:Ifmax=4.5A,Uf=5±0.5 large:Ifmax=4.5A,Uf=6.3±0.8V
Nominal input Power (1.0s) svir:spot0.6kW magna:spot3.5kW
Maximum continuum Rating 225W
Anode Calor Storage Capacity 30kJ
Scopum Anglus 12°
Scopum Material Wolframium
Filtration inhaerens Min 0.6mmAl aequivalens 75kV
Pondus approx540g

Detail Imagines

KL25-0.6-1.5-110

Environmental limites

Limites operandi (in oleo dielectric);

Oleum Temperature ………………………………………………………. .................................................10 ~ 60 °C

Oleum Pressura ................................................. 70 ~ 106 kPa

Shipping and Storage Limits: Temperature................................................. .....-40~ 70 °C

Uvor ................................................. .................................................... ........ 10 ~ 90 %

(Nulla condensatio)

Pressura atmosphaerica ..................................................... . . . . . . . . .

Aliquam commodo

Elevatus anode calor repono facultatem et refrigerationem
Constans princeps dose cede
Vita praeclara


  • Priora:
  • Next:

  • Minimum Order Quantity: 1pc

    Pretium: Negotium

    Packaging Details: 100pcs per currus vel nativus secundum quantitatem

    Delivery Time: 1~2 weeks secundum quantitatem

    Payment Terms: C% T / T in antecessum vel CONIUNCTIO OCCIDENTALIS

    Facultates copia: 1000pcs / mensis

    Epistulam tuam hic scribe et mitte nobis